ESP FlexiPoint Detector with Sounder & Strobe for Fire Detection

Prodotto
88.67 GBP Examine the detailed sheet with complete information, compare prices and find the features of PRODUCTNAME, on sale at the price of PRICE CURRENCY; it falls into the CATEGORY NAME category; the production is by MANUFACTURER NAME and the sale is managed by SELLER NAME.

FlexiPoint Detector with Sounder & Strobe for Fire Detection7 modes of fire detection including combined smoke/heat Complete with 3 sounder modes and LED strobe Built-in End of Line function Self-calibration every 6 hours Device wiring base included Continuous dust contamination monitoringTechnical Specification:Dimensions: Diameter: 107mmDepth: 75mmTemperature Range: Operating Temperature: -10°C to +50°CVoltage Range: Operating Voltage Range: 18V to 32V DCOperating Current: Quiescent: 101 uA (Typical)End of line ON if Applicable: +50 uA (Typical)Non Strobe Version: Alarm Sounding – Sounder High: 8.00 mA (Typical)Alarm Sounding – Sounder Low: 2.50 mA (Typical)Alarm Sounding – Sounder Off: 150 uA (Typical)Alarm Activated : 15.50 mA (Typical)Strobe Version: Alarm Sounding – Sounder High: 10.50 mA (Typical)Alarm Sounding – Sounder Low: 4.90 mA (Typical)Alarm Sounding – Sounder Off: 2.60 mA (Typical)Alarm Activated: 18.00 mA (Typical)LED Operation: Detector in Normal State (Smoke): Flash at 20 Second IntervalsDetector in Normal State (Heat): Double Flash at 20 Second IntervalsDetector at EOL: Flash at 5 Second IntervalsDetector in Fault: Flash at 1.3 Second IntervalsDetector Detecting Fire: Flash at 0.7 Second IntervalsDetector in Fire (Once Processed at Panel): ContinuousDevice Loading Units: Max Loading Units per Zone: 160 DLUNon Strobe Version: Sounder High: 8.0 DLUSounder Low: 6.5 DLUNo Sounder: 1.0 DLUStrobe Version: Sounder High: 16.0 DLUSounder Low: 8.0 DLUNo Sounder: 8.0 DLUVolume Level (@ 1m anechoic, Dual Tone): Sounder High: 90+ dB(A)Sounder Low: 70+ dB(A)Dimensions:

EAN: 5060224109984
Shipping Costs: 3.95 GBP
Availability: in stock
Delivery Times: 3 Days
Condition: new

Comparison of similar products

ESP FlexiPoint Detector with Sounder for Fire Detection ESP FlexiPoint Detector with Sounder for Fire Detection 72.52 GBP FlexiPoint Detector with Sounder for Fire Detection7 modes of fire detection including combined smoke/heat Complete with 3 sounder modes Built-in End of Line function Self-calibration every 6 hours Device wiring base included Continuous dust contamination monitoringTechnical Specification:Dimensions: Diameter: 107mmDepth: 75mmTemperature Range: Operating Temperature: -10°C to +50°CVoltage Range: Operating Voltage Range: 18V to 32V DCOperating Current: Quiescent: 101 uA (Typical)End of line ON if Applicable: +50 uA (Typical)Non Strobe Version: Alarm Sounding – Sounder High: 8.00 mA (Typical)Alarm Sounding – Sounder Low: 2.50 mA (Typical)Alarm Sounding – Sounder Off: 150 uA (Typical)Alarm Activated : 15.50 mA (Typical)Strobe Version: Alarm Sounding – Sounder High: 10.50 mA (Typical)Alarm Sounding – Sounder Low: 4.90 mA (Typical)Alarm Sounding – Sounder Off: 2.60 mA (Typical)Alarm Activated: 18.00 mA (Typical)LED Operation: Detector in Normal State (Smoke): Flash at 20 Second IntervalsDetector in Normal State (Heat): Double Flash at 20 Second IntervalsDetector at EOL: Flash at 5 Second IntervalsDetector in Fault: Flash at 1.3 Second IntervalsDetector Detecting Fire: Flash at 0.7 Second IntervalsDetector in Fire (Once Processed at Panel): ContinuousDevice Loading Units: Max Loading Units per Zone: 160 DLUNon Strobe Version: Sounder High: 8.0 DLUSounder Low: 6.5 DLUNo Sounder: 1.0 DLUStrobe Version: Sounder High: 16.0 DLUSounder Low: 8.0 DLUNo Sounder: 8.0 DLUVolume Level (@ 1m anechoic, Dual Tone): Sounder High: 90+ dB(A)Sounder Low: 70+ dB(A)Dimensions:
ESP FlexiPoint Detector for Fire Detection ESP FlexiPoint Detector for Fire Detection 52.56 GBP FlexiPoint Detector for Fire Detection7 modes of fire detection including combined smoke/heat Built-in End of Line function Self-calibration every 6 hours Continuous dust contamination monitoring Device wiring base includedTechnical Specification:Dimensions: Diameter: 107mmDepth: 75mmTemperature Range: Operating Temperature: -10°C to +50°CVoltage Range: Operating Voltage Range: 18V to 32V DCOperating Current: Quiescent: 101 uA (Typical)End of line ON if Applicable: +50 uA (Typical)Non Strobe Version: Alarm Sounding – Sounder High: 8.00 mA (Typical)Alarm Sounding – Sounder Low: 2.50 mA (Typical)Alarm Sounding – Sounder Off: 150 uA (Typical)Alarm Activated : 15.50 mA (Typical)Strobe Version: Alarm Sounding – Sounder High: 10.50 mA (Typical)Alarm Sounding – Sounder Low: 4.90 mA (Typical)Alarm Sounding – Sounder Off: 2.60 mA (Typical)Alarm Activated: 18.00 mA (Typical)LED Operation: Detector in Normal State (Smoke): Flash at 20 Second IntervalsDetector in Normal State (Heat): Double Flash at 20 Second IntervalsDetector at EOL: Flash at 5 Second IntervalsDetector in Fault: Flash at 1.3 Second IntervalsDetector Detecting Fire: Flash at 0.7 Second IntervalsDetector in Fire (Once Processed at Panel): ContinuousDevice Loading Units: Max Loading Units per Zone: 160 DLUNon Strobe Version: Sounder High: 8.0 DLUSounder Low: 6.5 DLUNo Sounder: 1.0 DLUStrobe Version: Sounder High: 16.0 DLUSounder Low: 8.0 DLUNo Sounder: 8.0 DLUVolume Level (@ 1m anechoic, Dual Tone): Sounder High: 90+ dB(A)Sounder Low: 70+ dB(A)Dimensions:
ESP Sounder Strobe for MAGDUO - Domed ESP Sounder Strobe for MAGDUO - Domed 70.53 GBP MAGDUO Sounder & Strobe Domed Complete with 3 sounder modes and LED strobe Volume level adjustment Built-in End of Line function Domed profile design Device wiring base includedTechnical Specification:Dimensions: Diameter: 105mmDepth: 45mm (Low Profile) / 62mm (Domed)Flush Depth Protruding: 34 mmSurface Depth: 62 mmTemperature Range: Operating Temperature: -10°C to +50°CVoltage Ranges: DC Output from Mains Powered Panel: 25.5 to 35V DCDC Output from Battery Powered Panel: 20 to 26V DCOperating Current (Typical): Quiescent: 223 uAEnd of line ON if applicable (in addition to Quiescent): 198 uAAlarm Sounding – Sounder High: 23.5 mAAlarm Sounding – Sounder Low: 15 mABeacon: 5.5 mAVolume Level (@ 1m anechoic, Dual Tone): Sounder High: 90+ dB(A)Sounder Low: 65+ dB(A)Device Loading Units: Max Device Loading Units per Zone: 160 DLUSounder High: 54.0 DLUSounder Low: 33.0 DLUBeacon: 33.0 DLULED Operation: EOL indication: 5 second intervalBeacon Operation: Period: 1sFlash Duration: 15 msIngress Protection : IP Rating: IP 21CDimensions:
ESP Banshee Sounder and Strobe ESP Banshee Sounder and Strobe 82.15 GBP Combined Banshee Sounder + (Red Lens) Strobe (97dBA)Sound Output - 89-110 dBA Flash rate - 60/minute Current - 40 mA plus sounder IP Rating - IP45Technical Specification:Termination: Screw terminals for 0.28mm² to 2.5mm²EN54-3 Voltage Range: 24VDC (20VDC to 28VDC)Operating voltage range: 9VDC to 30VDCCurrent Consumption: 5ma to37mA * dependant on tone typeOperating Temperature: -40°C - +70°CCase Material: ABSEnvironment Category: Type A - Shallow BaseIP45 Type-B Deep Base IP66Flash Current: 90mA @12VDC / 40mA @24VDCFlash Rate: 1/Sec
ESP Sounder Strobe for MAGDUO - Low Profile ESP Sounder Strobe for MAGDUO - Low Profile 68.2 GBP MAGDUO Sounder & Strobe Low Profile Complete with 3 sounder modes and LED strobe Volume level adjustment Built-in End of Line function Low profile design Device wiring base includedTechnical Specification:Dimensions: Diameter: 105mmDepth: 45mm (Low Profile) / 62mm (Domed)Flush Depth Protruding: 34 mmSurface Depth: 62 mmTemperature Range: Operating Temperature: -10°C to +50°CVoltage Ranges: DC Output from Mains Powered Panel: 25.5 to 35V DCDC Output from Battery Powered Panel: 20 to 26V DCOperating Current (Typical): Quiescent: 223 uAEnd of line ON if applicable (in addition to Quiescent): 198 uAAlarm Sounding – Sounder High: 23.5 mAAlarm Sounding – Sounder Low: 15 mABeacon: 5.5 mAVolume Level (@ 1m anechoic, Dual Tone): Sounder High: 90+ dB(A)Sounder Low: 65+ dB(A)Device Loading Units: Max Device Loading Units per Zone: 160 DLUSounder High: 54.0 DLUSounder Low: 33.0 DLUBeacon: 33.0 DLULED Operation: EOL indication: 5 second intervalBeacon Operation: Period: 1sFlash Duration: 15 msIngress Protection : IP Rating: IP 21CDimensions:
ESP Fireline 12V Conventional Optical Smoke Detector ESP Fireline 12V Conventional Optical Smoke Detector 32.03 GBP The PSD212 12 Volt optical smoke detector from ESP Fireline is a 12V proffesional EN grade detector which connects to virtually any 12V Intruder alarm system/panel via direct current. Connected in the same way as a PIR or mag contactact, this detector can be hard wired to a dedicated fire zone or any other spare zone on the panel, and eliminates the need for regular expensive battery changes . In the event of smoke detection this unit will contact the panel directly to trigger alarm sounders (Some panels include dedicated sounders for this purpose) to give you the ultimate edge in fire safety in your home or commercial premesis. In the event of a power cut to your alarm pannel this detector will continue to operate using backup battery power supplied gradually from the panel, ensuring your protection at all times. In the event of a fire this alarm will display bi-dircetional indicators to insinuate the direction of the trigger source, allowing you to potentially stop the problem, or to alter your escape route from an unseen dangerous gas/smoke source. Main Features: Professional grade optical detector Constant 12vDC feed from alarm panel No battery change necissary Back-up battery supply from panel Bi-directional visual indication Low current drain Technical Specifiaction: Voltage: 9 - 30V DC Standby Current @ 12v: < 50µA Alarm Current @12v: 29mA Wire Gauge: 0.4mm - 2.0mm Twin Operating Temp: -10°C to 60°C Test Facility: Simulated Smoke/ Heat Weight: 128g Dimensions: 120(D) x 40mm(H) Comes with a 1 year manufactures warranty Installation Instructions/Manual
ESP 2 Zone Two Wire Conventional Fire Alarm Kit Black ESP 2 Zone Two Wire Conventional Fire Alarm Kit Black 727.92 GBP 2 Zone Two Wire Conventional Fire Alarm KitMAGDUO2B 2 zone Two Wire fire panel (Requires 2 x 12v 3.2ah SLA Batteries) 6 x MAGDUOSHDS Selectable optical smoke / heat detectors with inbuilt sounders & bases included 1 x MAGDUOSHDSS Selectable optical smoke / heat detectors with inbuilt sounder & strobe, base included 2 x MAGDUOCP Resettable call points 1 x MAGDUOSHDRT Head removal tool
ESP 2 Zone Two Wire Conventional Fire Alarm Kit Grey ESP 2 Zone Two Wire Conventional Fire Alarm Kit Grey 727.92 GBP 2 Zone Two Wire Conventional Fire Alarm KitMAGDUO2 2 zone Two Wire fire panel (Requires 2 x 12v 3.2ah SLA Batteries) 6 x MAGDUOSHDS Selectable optical smoke / heat detectors with inbuilt sounders & bases included 1 x MAGDUOSHDSS Selectable optical smoke / heat detectors with inbuilt sounder & strobe, base included 2 x MAGDUOCP Resettable call points 1 x MAGDUOSHDRT Head removal tool