Lewden 6A 6kA 30mA Single Pole 1 Module C Curve RCBO
54.42 GBP
Access the complete information sheet, compare prices and discover the features of PRODUCTNAME, available at the price of PRICE CURRENCY; it fits into the CATEGORY NAME category; the product is sold by SELLER NAME and made by MANUFACTURER NAME.
10kA RCBOsDesigned and tested for use with Lewden branded distribution boards.Residual current circuit breaker with integral overcurrent protection.Class A.Single module RCBOs are suitable for use in TN-S, TN-C-S, & TT network systems.Technical Specification:Rated Current: 6ATrip Curve: CRCD Class: AFor Cables ø: 1-16mm²Breaking Capacity: 10Frequency: 50/60HzPoles: 1P+NRated Operating Voltage: 230VExecution: DIN RAIL MOUNTINGResidual Current: 30mANet Weight: 0.16KGDimensions: 126.4x18x76.1mm (HWD)Standards: EN 61009-2-1/A11:1998
EAN: 5026992048917
Shipping Costs: 3.95 GBP
Availability: in stock
Delivery Times: 3 Days
Condition: new
Comparison of similar products
Lewden 10A 6kA 30mA Single Pole 1 Module C Curve RCBO
62.81 GBP
10kA RCBOsDesigned and tested for use with Lewden branded distribution boards.Residual current circuit breaker with integral overcurrent protection.Class A.Single module RCBOs are suitable for use in TN-S, TN-C-S, & TT network systems.Technical Specification:Rated Current: 10ATrip Curve: CRCD Class: AFor Cables ø: 1-16mm²Breaking Capacity: 10Frequency: 50/60HzPoles: 1P+NRated Operating Voltage: 230VExecution: DIN RAIL MOUNTINGResidual Current: 30mANet Weight: 0.16KGDimensions: 126.4x18x76.1mm (HWD)Standards: EN 61009-2-1/A11:1998
Lewden 16A 6kA 30mA Single Pole 1 Module C Curve RCBO
63.23 GBP
10kA RCBOsDesigned and tested for use with Lewden branded distribution boards.Residual current circuit breaker with integral overcurrent protection.Class A.Single module RCBOs are suitable for use in TN-S, TN-C-S, & TT network systems.Technical Specification:Rated Current: 16ATrip Curve: CRCD Class: AFor Cables ø: 1-16mm²Breaking Capacity: 10Frequency: 50/60HzPoles: 1P+NRated Operating Voltage: 230VExecution: DIN RAIL MOUNTINGResidual Current: 30mANet Weight: 0.16KGDimensions: 126.4x18x76.1mm (HWD)Standards: EN 61009-2-1/A11:1998
Lewden 40A 6kA 30mA Single Pole 1 Module C Curve RCBO
39.89 GBP
10kA RCBOsDesigned and tested for use with Lewden branded distribution boards.Residual current circuit breaker with integral overcurrent protection.Class A.Single module RCBOs are suitable for use in TN-S, TN-C-S, & TT network systems.Technical Specification:Rated Current: 40ATrip Curve: CRCD Class: AFor Cables ø: 1-16mm²Breaking Capacity: 10Frequency: 50/60HzPoles: 1P+NRated Operating Voltage: 230VExecution: DIN RAIL MOUNTINGResidual Current: 30mANet Weight: 0.16KGDimensions: 126.4x18x76.1mm (HWD)Standards: EN 61009-2-1/A11:1998
Lewden 32A 6kA 30mA Single Pole 1 Module C Curve RCBO
39.89 GBP
10kA RCBOsDesigned and tested for use with Lewden branded distribution boards.Residual current circuit breaker with integral overcurrent protection.Class A.Single module RCBOs are suitable for use in TN-S, TN-C-S, & TT network systems.Technical Specification:Rated Current: 32ATrip Curve: CRCD Class: AFor Cables ø: 1-16mm²Breaking Capacity: 10Frequency: 50/60HzPoles: 1P+NRated Operating Voltage: 230VExecution: DIN RAIL MOUNTINGResidual Current: 30mANet Weight: 0.16KGDimensions: 126.4x18x76.1mm (HWD)Standards: EN 61009-2-1/A11:1998
Lewden 20A 6kA 30mA Single Pole 1 Module C Curve RCBO
27.16 GBP
10kA RCBOsDesigned and tested for use with Lewden branded distribution boards.Residual current circuit breaker with integral overcurrent protection.Class A.Single module RCBOs are suitable for use in TN-S, TN-C-S, & TT network systems.Technical Specification:Rated Current: 20ATrip Curve: CRCD Class: AFor Cables ø: 1-16mm²Breaking Capacity: 10Frequency: 50HzPoles: 1P+NRated Operating Voltage: 230VExecution: DIN RAIL MOUNTINGResidual Current: 30mANet Weight: 0.16KGDimensions: 126.4x18x76.1mm (HWD)Standards: EN 61009-2-1/A11:1998
Lewden 6KA Rcbo Single Pole 6A 30MA B Curve 1 Mod Type a White Rcbo-06/30/Spa
19.65 GBP
The Lewden is a 1 Module 6A x 6k A x 30m A Single Pole Type A RCBO with B tripping characteristics in the Pro range of residential consumer units. These RCBOs provide residual current and earth leakage protection alongside overcurrent protection, all within one compact unit. Combining overcurrent and earth fault protection into one unit allows only the faulty circuit to be interrupted, ideal for improving the safety of circuits, protecting key circuits and reducing unnecessary tripping. Their compact construction and 300mm blue neutral flying lead are ideal for fast, stress-free installations.
Lewden 6A 10kA Single Pole C Curve MCB
9.25 GBP
10kA MCBsDesigned and tested for use with Lewden branded distribution boardsThermal magnetic miniature circuit breakerC typeTechnical Specification:For Cables ø: 1-25 mm²Breaking Capacity: 10Trip Curve: CFrequency: 50/60HzPoles: 1Rated Operating Voltage: 230-400V~Execution: DIN RAIL MOUNTINGRated Current: 6ADimensions: 88x17.8x69.5mm (HWD)Net Weight: 0.10KGStandards: IEC 60947-2:2016, IEC 60898-1:2015, EN 60898-1:2019, BS EN 60898-1:2019
Schneider Electric - Schneider A9N21444 - Prodis, DT40 vigi Differential Circuit Breaker 1P+N 6KA 16A 30MA Curve c Type ac
145.82 GBP
General description The Schneider A9N21444 - Prodis DT40 VIGI Differential Circuit Breaker is designed for reliable protection in electrical installations. It features a compact design and is suitable for various applications. Technical specifications Product type: Differential circuit breaker Rated operating current: 16 A Network type: AC Pole description: 1P + N (Neutral pole position: Left) Trigger technology: Thermal-magnetic Trigger curve: C Differential sensitivity: 30 mA Differential time delay: Instantaneous Differential class: Class AC Breaking capacity: Icn 4.5 kA at 230 V AC 50/60 Hz in accordance with EN 61009
Lewden 6A 10kA Triple Pole C Curve MCB
21.15 GBP
10kA MCBsDesigned and tested for use with Lewden branded distribution boardsThermal magnetic miniature circuit breakerC typeTechnical Specification:For Cables ø: 1-25 mm²Breaking Capacity: 10Trip Curve: CFrequency: 50/60HzPoles: 3Rated Operating Voltage: 230-400V~Execution: DIN RAIL MOUNTINGRated Current: 6ADimensions: 69.5x54x88mmNet Weight: 0.32KGStandards: BS EN 60898-1:2019, EN 60898-1:2019, IEC 60947-2:2016, IEC 60898-1:2015
Lewden Single Pole Type B 6A 10KA MCB E10-1B06
11.71 GBP
The Lewden range of circuit protection devices are designed and tested for use with Lewden branded distribution boards. This device must be installed by a skilful electrician in accordance with the latest edition of the IET wiring regulations for electrical installations BS7671
Techna RTECX6-2C10-030 6kA RCBO 2 Pole C 10A 30mA Type AC
45.77 GBP
Techna-RTECX6-2C10-030-6kA-RCBO-2-Pole-10A-Techna-RTECX6-2C10-030-p-This-RCBO-combines-residual-current-earth-leakage-protection-and-overload-short-circuit-protection-in-a-single-unit-The-device-features-dual-pole-switching-and-is-suitable-as-a-replacement-for-an-RCCB-MCB-combination-p-Techna-RTECX6-2C10-030-6kA-RCBO-2-Pole-C-10A-30mA-Type-AC
Lewden 6A 10kA Triple Pole D Curve MCB
32.07 GBP
10kA MCBsDesigned and tested for use with Lewden branded distribution boardsThermal magnetic miniature circuit breakerD typeTechnical Specification:For Cables ø: 1-25 mm²Breaking Capacity: 10Trip Curve: DFrequency: 50/60HzPoles: 3Rated Operating Voltage: 230-400V~Execution: DIN RAIL MOUNTINGRated Current: 6ADimensions: 69.5x54x88Net Weight: 0.32KGStandards: EN 60898-1:2019, IEC 60947-2:2016, IEC 60898-1:2015, BS EN 60898-1:2019
ESR RCBO C Curve 6KA 1 Pole Domestic Consumer Unit Circuit Breaker - 6A 30mA
13.63 GBP
The Single Pole C Curve RCBO Breakers from ESR are available in a range of amp ratings including 6 Amp, 16 Amp and 32 Amp. This range includes the RCBO1-630C, RCBO1-1630C and RCBO1-3230C models. An RCBO circuit breaker is a current breaker comprised of RCD and MCB functions designed to protect the user and their property from overloads and short circuits by breaking the current as is passes through your consumer unit in the event of suggested dangerous earth leakage. RCBOs are known to save lives and are a commonly used component in domestic consumer unit configurations. These RCBO modules will use 1 module/way on your consumer unit rail bar, and are ideal for heavy domestic use in the C curve option such as when wiring circuitry for motorized appliances such as washing machines, tumble driers etc, or where fluorescent lighting is used. All models in this list will trip at 30mA. C curve RCBOs will trip at 5-10 times the rated current. Therefore we advise consulting your electrician if you are unsure which curve or current is right for your desired application, as the wrong type may cause unnecessary tripping or create a potential hazard. Main Features: Single pole RCBO circuit breakers in a range of current and curve options Easily installed in your ESR modular consumer unit Safe and reliable product that is known to save lives and severely reduce risk of property damage Technical Specification: Voltage: 230V Frequency: 50 Hz Modular size: 1 Module/way Pole: Single Pole Rated Trip Current = 30mA BS EN61009-1 Dimensions (H x L x W): 142mm x 80mm x 39mm (approx) Models in this range: RCBO1-630C - C Curve 6KA Single Pole RCBO - 6A 30mA RCBO1-1630C - C Curve 6KA Single Pole RCBO - 16A 30mA RCBO1-3230C - C Curve 6KA Single Pole RCBO - 32A 30mA These Modules are ideal for use with the ESR Mains Switch Consumer Unit
Siemens 5SU13547KK06 RCBO 6A Type A 230V 1P+N 30mA C-Char 10kA
93.25 GBP
Siemens Circuit Breakers RCBO 613704 - Siemens 5SU13547KK06, The Siemens 5SU13547KK06 RCBO is a 2-pin circuit breaker designed for protection with a rated current of 6 A and a sensitivity of 0.03 A at 230 V. It combines residual current and overcurrent protection, making it ideal for residential and commercial electrical systems. This RCBO is typically used to safeguard against electrical faults such as short circuits and earth leakages. Siemens 5SU13547KK06 RCBO 6A Type A 230V 1P+N 30mA C-Char 10kA
Lewden 6A 10kA Triple Pole B Curve MCB
22.27 GBP
10kA MCBsDesigned and tested for use with Lewden branded distribution boardsThermal magnetic miniature circuit breakerB type Technical Specification:For Cables ø: 1-25 mm²Breaking Capacity: 10Trip Curve: BFrequency: 50/60HzPoles: 3Rated Operating Voltage: 230-400V~Execution: DIN RAIL MOUNTINGRated Current: 6ADimensions: 69.5x54x88mmNet Weight: 0.32KGStandards: BS EN 60898-1:2019, EN 60898-1:2019, IEC 60898-1:2015, IEC 60947-2:2016
Lewden 6A 10kA Double Pole D Curve MCB
27.91 GBP
10kA MCBsDesigned and tested for use with Lewden branded distribution boardsThermal magnetic miniature circuit breakerD typeTechnical Specification:For Cables ø: 1-25 mm²Breaking Capacity: 10Trip Curve: DFrequency: 50/60HzPoles: 2Rated Operating Voltage: 230-400V~Execution: DIN RAIL MOUNTINGRated Current: 6ADimensions: 69.5x36x88mmNet Weight: 0.21KGStandards: BS EN 60898-1:2019, IEC 60898-1:2015, EN 60898-1:2019, IEC 60947-2:2016
Siemens 5SU13566KK13 RCBO 13A 30mA 230V 1P+N Type A 10kA C-Char 6A
53.63 GBP
Siemens Circuit Breakers Switch 613705 - Siemens 5SU13566KK13, Siemens manufactures the 5SU13566KK13, a residual current circuit breaker with a 13 A current rating and 0.03 A earth leakage sensitivity, suitable for 230 V systems. This device combines circuit breaking and residual current protection for enhanced safety. It is typically used to provide personal protection and prevent electrical shocks in residential and commercial installations. Siemens 5SU13566KK13 RCBO 13A 30mA 230V 1P+N Type A 10kA C-Char 6A
Siemens 5SU13566KK06 RCBO Switch 6A 230V 10kA 1P+N 30mA type A
53.57 GBP
Siemens Circuit Breakers Switch 613705 - Siemens 5SU13566KK06, The Siemens 5SU13566KK06 Switch is a residual current circuit breaker with a rating of 6 A and 0.03 A sensitivity, designed for 230 V systems. This device offers personal protection by automatically detecting and interrupting earth leakage currents, making it suitable for residential and commercial electrical installations. It combines an earth leakage circuit breaker with a standard circuit breaker to enhance safety and prevent electrical faults. Siemens 5SU13566KK06 RCBO Switch 6A 230V 10kA 1P+N 30mA type A
Siemens 5SV13167KK16 RCBO 1P+N 16A 30mA 6kA type A for touch prote...
56.38 GBP
Siemens Circuit Breakers RCBO 613704 - Siemens 5SV13167KK16, The Siemens RCBO 5SV1316-7KK16 is a circuit protection device rated at 16 A with a residual current of 0.03 A, suitable for 230 V systems. It combines the functionality of a miniature circuit breaker and a residual current circuit breaker, offering overcurrent and earth fault protection. Ideal for residential and commercial electrical installations, it ensures safety and prevents electrical hazards. Siemens 5SV13167KK16 RCBO 1P+N 16A 30mA 6kA type A for touch protection
Siemens 5SV13163KK16 RCBO 16A 230V 30mA 1P+N 6kA type F K B16 compact
126.5 GBP
Siemens Circuit Breakers RCBO 613704 - Siemens 5SV13163KK16, The Siemens 5SV1316-3KK16 RCBO is a circuit breaker offering a current rating of 16 A and a residual current rating of 0.03 A for enhanced electrical safety. Operating at 230 V, it combines overcurrent and earth fault protection, making it ideal for residential and commercial electrical systems. Typical applications include safeguarding circuits in homes, offices, and similar environments against electrical faults. Siemens 5SV13163KK16 RCBO 16A 230V 30mA 1P+N 6kA type F K B16 compact